Fault Ride-Through Capability of DSTATCOM for Distributed Wind Generation System
نویسندگان
چکیده
منابع مشابه
Control System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System
In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting of permanent magnet synchronous generator (PMSG) ...
متن کاملCoordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms
Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaa...
متن کاملSecond-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancement.
This paper deals with the fault ride-through capability assessment of a doubly fed induction generator-based wind turbine using a high-order sliding mode control. Indeed, it has been recently suggested that sliding mode control is a solution of choice to the fault ride-through problem. In this context, this paper proposes a second-order sliding mode as an improved solution that handle the class...
متن کاملEnhancement of Fault Ride through Capability of a Wind Driven Dfig Connected to the Grid
Enhancement of fault ride-through (FRT) capability and subsequent improvement of rotor speed stability of wind farms equipped with doubly fed induction generator (DFIG) is the objective of this paper. The objective is achieved by employing a novel FRT scheme with suitable control strategy. The proposed FRT scheme, which is connected between the rotor circuit and dc link capacitor in parallel wi...
متن کاملWind Turbine Control Design to Enhance the Fault Ride- Through Capability
This paper presents a control strategy for wind turbines to enhance their fault ride-through capability. The controller design is based on pitch controlled variable speed wind turbine equipped with doubly-fed induction generator (DFIG). The fault ride-through is realized by injecting a crowbar with variable resistance on the generator rotor circuit. To reduce the mechanical loads induced by gri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Power Electronics and Drive Systems (IJPEDS)
سال: 2015
ISSN: 2088-8694,2088-8694
DOI: 10.11591/ijpeds.v6.i2.pp348-355