Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Transformer Fault Detection Using Frequency Response Analysis

Power transformers prove to be a vital element or tool in electrical power supply and transmission system. They are capital intensive units and need to be monitored for faults. Faults in transformers leading to their failure are repugnant. Thus, there is a need to detect such faults at an initial level. This paper aims to detect, diagnose the nature and cause of mechanical faults, their identit...

متن کامل

Transfer Function of Transformer Winding for Frequency Response Analysis Based on Traveling Wave Theory

This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived...

متن کامل

Comparison of Impulse Wave and Sweep Frequency Response Analysis Methods for Diagnosis of Transformer Winding Faults

Monitoring of winding faults is the most important item used to determine the maintenance status of a transformer. Commonly used methods for winding-fault diagnosis require the transformer to exit operation before testing and an external exciting signal, whether the transformer is malfunctioning or not. However, if an overvoltage signal can be regarded as a broadband excitation source for fault...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....