Transient overvoltages appearing at line terminal of power transformer HV windings can cause failure of winding insulation. The failure can be from winding to ground or between turns or sections of winding. In most of the cases, failure from winding to ground can be detected by changes in the wave shape of surge voltage appearing at line terminal. However, detection of insulation failure betwee...
متن کاملRecognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces
Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملIdentification of Power Transformer Winding Mechanical Fault Types Based on Online IFRA by Support Vector Machine
A transformer is the most valuable and expensive property for power utility, thus ensuring its reliable operation is a major task for both operators and researchers. Online impulse frequency response analysis has proven to be a promising technique for detecting transformer internal winding mechanical deformation faults when a power transformer is in service. However, as so far, there is still n...
متن کاملA High Frequency Transformer Winding Model for FRA Applications
Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrical Systems and Information Technology
سال: 2015
ISSN: 2314-7172
DOI: 10.1016/j.jesit.2015.06.004