FATIGUE TESTS OF A COMPOSITE GIRDER WITH CORRUGATED WEB
نویسندگان
چکیده
منابع مشابه
Analysis of Girder Differential Deflection and Web Gap Stress for Rapid Assessment of Distortional Fatigue in Multi-Girder Steel Bridges
Distortion-induced fatigue cracking in unstiffened web gaps is common in steel bridges. Previous research by the Minnesota Department of Transportation (Mn/DOT) developed methods to predict the peak web gap stress and maximum differential deflection based upon field data and finite element analyses from two skew supported steel bridges with staggered bent-plate and cross-brace diaphragms, respe...
متن کاملThe Stress-related Damping Ratio of Box Girder with Corrugated Steel Webs
In this paper, the stress-related damping ratio formula of box girder with corrugated steel webs is introduced. Using response spectrum method, an iterative algorithm is proposed to calculate the seismic response and the stressrelated damping ratio under different seismic intensities. Based on a simply supported composite box girder bridge with corrugated steel webs, the stress-related damping ...
متن کاملfinite element based fatigue assessment of corrugated steel web beams in highway bridges
this paper presents a finite element analysis and its related experimental test of corrugated steel web beams subjected to fatigue loading. a particular focus in this study was set on the fatigue failure arising from the web-to-flange welded joint of the corrugated steel web beam. a detailed three-dimensional finite element model which explicitly includes the geometry of the web-to-flange welds...
متن کاملTheoretical and Experimental Study on Natural Frequency of Externally Prestressed Box-Girder with Corrugated Steel Webs
Abstract: Based on the characteristics of box girder with corrugated steel webs, the existing prestressing force, the effect of shear deformation of composite girder on the deflection, “folding effect” in longitudinal direction of corrugate steel webs and the arrangement of external tendons were considered comprehensively. With the experiment results of five literatures integrated, N/fcA (the a...
متن کاملExperimental Study on the Fire Resistance Performance of Prestressed Composite Beam with Corrugated Web under Standard Fire with Loading Condition
In this study, fire resistance tests were performed on a conventional slim floor beam and a prestressed composite beam with corrugated webs, which is suitable for a long-span structure with a reduction in story height by utilizing the prestress and accordion effect. In the fire test program, the ISO 834 standard fire curve was adopted. Key test variables were the effect of prestress, shape of c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Doboku Gakkai Ronbunshu
سال: 2001
ISSN: 0289-7806,1882-7187
DOI: 10.2208/jscej.2001.668_55