Fatigue. Fatigue Behaviour and Fracture Mechanisms in 6063 Aluminium Alloy.
نویسندگان
چکیده
منابع مشابه
Fatigue and Anisotropic behaviours of cold rolled AA1200 Aluminium Alloy
This study examines the fatigue and anisotropy behaviour of cold rolled AA1200 aluminium alloy for light weight automotive connecting rod application. Aluminium (Al) 1200 ingots were melted at temperature of 680 0C (after one hour of heating) cast in sand mould and cast samples homogenized for 6 hrs at 480 0C. The cold rolling process was carried out after homogenisation for 10, 20, 30, 40 and ...
متن کاملFatigue Behaviour in Fine Grained Aluminium Alloys
The effects of alloy production method on microstructure and hence fatigue crack growth rate and fracture mechanism have been examined for a variety of fine-grained/high dispersoid Al-Li-Mg-Zr and Al-Li-Cu-Mg-Zr alloys. Microstructures have been assessed by scanning and transmission electron microcopy, together with electron back scattered diffraction pattern assessment. In these fine-grained/h...
متن کاملFatigue of Friction Stir Welded 2024-T351 Aluminium Alloy
Fatigue failure characteristics of friction stir welds in 13mm gauge 2024-T351 plate have been assessed. Failure occurred from either the weld region (nugget/flow arm) or from the material immediately surrounding the weld. Fatigue failure from the surrounding material was essentially conventional, initiating from large S-phase intermetallic particles and growing in a macroscopic mode I manner. ...
متن کاملStudies of Corrosion of Aluminium and 6063 Aluminium Alloy in Phosphoric Acid Medium
The corrosion behaviour of aluminium and6063 aluminium alloy was investigated in phosphoric acid of different concentrations at different temperatures. The study was done by electrochemical method, using Tafel polarization and electrochemical impedance spectroscopy (EIS) techniques. The kinetic parameters and thermodynamic parameters were calculated using Arrhenius theory and transition state t...
متن کاملFatigue and corrosion fatigue properties of Ti-6Al-4V implant grade titanium alloy in Ringer solution
Nowadays modification of metallic biomaterials which are used as implants for bone and hard tissues replacement is considered as an important subject. In the current study, corrosion fatigue properties of Ti-6Al-4V alloy investigated via Rotating-Bending standard test method and then, the results compared with the fatigue properties of the specimens tested in the same conditions. Scanning elect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Society of Materials Science, Japan
سال: 2001
ISSN: 1880-7488,0514-5163
DOI: 10.2472/jsms.50.1062