Fat-water separated myocardial T1 mapping with IDEAL-T1 saturation recovery gradient echo imaging
نویسندگان
چکیده
منابع مشابه
Fat-water separated myocardial T1 mapping with IDEAL-T1 saturation recovery gradient echo imaging
Background Myocardial T1 mapping is emerging as powerful tool for tissue characterization, however the presence of intramyocardial or epicardial fat can contaminate T1 values through partial voluming, or preclude analysis, particularly in areas of infarct or thin walled myocardium, such as the right ventricle. We propose and evaluate a new combined fat-water separated saturation-recovery imagin...
متن کامل3D saturation recovery imaging for free breathing myocardial T1 mapping
Background Longitudinal magnetization relaxation time (T1) mapping can overcome limitations of late gadolinium enhancement for the detection of diffuse fibrosis in the myocardium. Several T1 mapping methods have been proposed in recent years; however most of them are limited to 2D breath-hold acquisitions with associated limitations in signal-to-noise ratio (SNR) and spatial resolution. A MOdif...
متن کاملPilot data of right ventricular myocardial T1 quantification by free-breathing fat-water separated dark blood saturation-recovery imaging
Background Right ventricular (RV) T1 quantification is desirable in managing congenital heart disease and pulmonary hypertension patients where RV fibrosis is implicated. RV T1 quantification is technically difficult because of the thin trabeculated mobile wall of complex geometry, impacted by adjacent blood and epicardial fat, plus proximity to sternal wires in some cases. Prior work has measu...
متن کاملOvarian masses: MR imaging with T1-weighted 3-dimensional gradient-echo IDEAL water-fat separation sequence at 3T.
PURPOSE We retrospectively compared the efficacy of 3-dimensional (3D) gradient-echo magnetic resonance T(1)-weighted sequence using the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) technique with the efficacy of conventional 3D gradient-echo sequences for diagnosing ovarian masses at 3T. MATERIALS AND METHODS In images of 32 women (mean ag...
متن کاملSaturation Recovery Myocardial T1 Mapping with a Composite Radiofrequency Pulse on a 3T MR Imaging System
PURPOSE To evaluate the effect of a composite radiofrequency (RF) pulse on saturation recovery (SR) myocardial T1 mapping using a 3T MR system. MATERIALS AND METHODS Phantom and in vivo studies were performed with a clinical 3T MR scanner. Accuracy and reproducibility of the SR T1 mapping using conventional and composite RF pulses were first compared in phantom experiments. An in vivo study w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2014
ISSN: 1532-429X
DOI: 10.1186/1532-429x-16-s1-p65