Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
نویسندگان
چکیده
منابع مشابه
Evidence of multiple pathways capable of emitting peroxyoxalate chemiluminescence using a charge coupled device spectrometer.
Peroxyoxalate chemiluminescence (PO-CL) spectra obtained simultaneously and continuously using a CCD spectrometer provide evidence of the complexity of PO-CL reactions.
متن کاملA fast, direct x-ray detection charge-coupled device.
A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 microm thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output po...
متن کاملVertical Accuracy Simulation of Stereo Mapping Using a Small Matrix Charge-Coupled Device
At present, without ground control points (GCPs), the positioning accuracy of remote sensing images often fails to meet the growing requirements for mapping accuracy. Multi-load synergy to improve accuracy without GCPs by eliminating the impact of stereo accuracy, which is caused by on-orbit measurement error, is urgently needed to improve large-scale mapping. In this study, we analyzed error s...
متن کاملLong-path measurement of atmospheric NO2 with an obstruction flashlight and a charge-coupled-device spectrometer.
A novel method of differential optical absorption spectroscopy (DOAS) is proposed and demonstrated to monitor the concentration of atmospheric pollutant gas. In contrast to conventional DOAS measurements with continuous light sources, the present method relies on white flashlights such as aviation obstruction lights that are generally installed on tall constructions. A simple detection system i...
متن کاملA high-accuracy universal polarimeter study of optical anisotropy and optical activity in laminated collagen membranes.
A novel method for fabricating anisotropic collagen membranes, which regulate the preferred orientation, is developed. The high-accuracy universal polarimeter (HAUP) method is used for simultaneous and quantitative evaluations of the optical anisotropy and optical activity. The evaluation of these optical quantities, enabled by the HAUP method, is beneficial to the field of tissue engineering.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: AIP Advances
سال: 2017
ISSN: 2158-3226
DOI: 10.1063/1.4977440