Fast-Transient Repetitive Control Strategy for a Three-phase LCL Filter-based Shunt Active Power Filter
نویسندگان
چکیده
منابع مشابه
Optimum Control Strategy of Three-Phase Shunt Active Filter System
The aim of this paper is to identify an optimum control strategy of three-phase shunt active filters to minimize the total harmonic distortion factor of the supply current. A classical PIPI cascade control solution of the output current of the active filter and the voltage across the DC capacitor based on Modulus–Optimum criterion is taken into consideration. The control system operation has be...
متن کاملControl Strategy for Three Phase Shunt Active Power Filter with Minimum Current Measurements
The active power filter has been proved to be an effective method to mitigate harmonic currents generated by nonlinear loads as well as to compensate reactive power. The methods of harmonic current detection play a crucial part in the performance of active power filter (APF). This paper presents a new control strategy in which two shunt active power filter configurations are developed in order ...
متن کاملFinite Control Set Model Predictive Control for a Three-Phase Shunt Active Power Filter with a Kalman Filter-Based Estimation
In this paper, the finite control set model predictive control is combined with the vector operation technique to be applied in the control of a three-phase active power filter. Typically, in the finite control set technique applied to three-phase power converters, eight different vectors are considered in order to obtain the optimum control signal by minimizing a cost function. On the other ha...
متن کاملA Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter
The three-phase three-wire neutral-point-clamped shunt active power filter (NPC-SAPF), which most adopts classical closed-loop feedback control methods such as proportional-integral (PI), proportional-resonant (PR) and repetitive control, can only output 1st–25th harmonic currents with 10–20 kHz switching frequency. The reason for this is that the controller design must make a compromise betwee...
متن کاملA Novel Design and Optimization Method of an $LCL$ Filter for a Shunt Active Power Filter
This paper analyses the characteristics of LCL filter in active power filter (APF) and provides an accurate for mula to determine the resonant frequency of system. Based on a single-phase equivalent circuit model, a systematic approach to design APF with LCL filter is proposed. Total inductance is determined by the capability of APF. Moreover, damping ratio, resonant frequency and attenuation d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Power Electronics
سال: 2014
ISSN: 1598-2092
DOI: 10.6113/jpe.2014.14.2.392