Fast spectrally encoded Mueller optical scanning microscopy
نویسندگان
چکیده
منابع مشابه
Heterodyne near-field scanning optical microscopy with spectrally broad sources.
We propose to use low-coherence-length cw optical sources with a broad spectrum in heterodyne near-field scanning microscopy in order to imitate optical pulse propagation and to obtain information about spectrally variant properties of nanophotonic components. The dispersion difference in the interferometer arms for a symmetric acousto-optic modulator arrangement is shown to be negligible over ...
متن کاملSpectrally encoded confocal scanning laser ophthalmoscopy.
We present in vivo human fundus imaging using a fiber-based confocal scanning laser ophthalmoscope (SLO). Spectrally encoded confocal scanning laser ophthalmoscopy (SECSLO) utilizes a spectral encoding technique in one dimension, combined with single-axis lateral scanning, to create video-rate reflectivity maps of the fundus. This implementation of the SLO allows for high-contrast high-resoluti...
متن کاملRapid wavelength-swept spectrally encoded confocal microscopy.
Spectrally encoded confocal microscopy (SECM) is a technique that allows confocal microscopy to be performed through the confines of a narrow diameter optical fiber probe. We present a novel scheme for performing SECM in which a rapid wavelength swept source is used. The system allows large field of view images to be acquired at rates up to 30 frames/second. Images of resolution targets and tis...
متن کاملSpectrally Encoded Confocal Microscopy for Guiding Lumpectomy
Complete removal of breast cancer during a single breastconserving lumpectomy procedure is often challenging due to the lack of adequate intraoperative tools to accurately determine the margin status. About one-third of lumpectomy patients are found to have positive margins upon final histologic analysis, which usually is reported within a week after surgery. These patients are then required to...
متن کاملSpectrally encoded extended source optical coherence tomography.
We have developed an extended source optical coherence tomography (SEES-OCT) technique in an attempt to improve signal strength for ophthalmic imaging. A line illumination with a visual angle of 7.9 mrad is produced by introducing a dispersive element in the infinity space of the sample arm. The maximum permissible exposure (MPE) of such an extended source is 3.1 times larger than that of a "st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scientific Reports
سال: 2019
ISSN: 2045-2322
DOI: 10.1038/s41598-019-40467-z