منابع مشابه
Improvement of Response Properties of MR-Fluid Actuator by Torque Feedback Control
Magnetorheological (MR) fluids are substances that respond to an applied magnetic field with a change in their rheological behavior. Though they are functionally similar to electrorheological (ER) fluids, MR fluids exhibit much higher yield strengths for applied magnetic fields than ER fluids for applied electric fields. The devices using MR fluids have an ability to provide high-torque, low-in...
متن کاملFast-Response Electrostatic Actuator Based on Nano-Gap
The possibility of constructing new high-performance electrostatic fast actuators based on energy transformation in nanometer gaps is considered. The construction and the properties of the operation of such devices as well as their typical parameters are described. The drives are based on ferroelectrics with high values of dielectric permittivity (above 1000). They can be constructed using micr...
متن کاملFast fluid-attenuated inversion-recovery MR of intracranial infections.
PURPOSE To assess the usefulness of fast fluid-attenuated inversion-recovery (FLAIR) MR sequences in the diagnosis of intracranial infectious diseases. METHODS We compared fast FLAIR images with conventional spin-echo images (T1- and T2-weighted) obtained in 20 patients with infectious diseases (six with encephalitis, five with brain abscesses, three with meningitis, two with meningoencephali...
متن کاملA novel bi-directional deformable fluid actuator
The deformable fluid actuators available on the market, i.e. pneumatic muscles and pneumatic springs, are designed to mainly exert compressive or tensile forces. This paper deals with a novel fluid deformable actuator, with three membranes, called BiFAc3, whose particular feature is the ability to exert both tensile and compressive forces. The structure of the actuator is based on three cylindr...
متن کاملFast MR Spectroscopic Imaging
MR spectroscopic imaging (MRSI) has become widely available as a research tool for mapping tissue metabolic status. Clinical research applications have been limited by intrinsically low sensitivity and by time-consuming phase encoding techniques that are used with conventional MRSI. The long encoding times limit volume coverage, introduce motion sensitivity and tax patient tolerance. The increa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JSME International Journal Series C
سال: 2004
ISSN: 1344-7653,1347-538X
DOI: 10.1299/jsmec.47.783