Fast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model

The highly conformal dose distributions produced by scanned proton pencil beams (PBs) are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy. The ability to calculate the dose in real-time as it is being delivered would enable, for example, online dose monitoring, and is therefore highly desirable. We have previously described an implementation of a...

متن کامل

GPU-based ultra-fast dose calculation using a finite size pencil beam model.

Online adaptive radiation therapy (ART) is an attractive concept that promises the ability to deliver an optimal treatment in response to the inter-fraction variability in patient anatomy. However, it has yet to be realized due to technical limitations. Fast dose deposit coefficient calculation is a critical component of the online planning process that is required for plan optimization of inte...

متن کامل

A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

Recent developments in radiation therapy have been focused on applications of charged particles, especially—protons. Proton therapy can allow higher dose conformality compared to conventional radiation therapy. Dose calculations have an integral role in the successful application of proton therapy. Over the years several dose calculation methods have been proposed in proton therapy. A common ch...

متن کامل

Golden beam data for proton pencil-beam scanning.

Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...

متن کامل

Biological Dose Estimation Model for Proton Beam Therapy

Purpose: The recommended value for the relative biological effectiveness (RBE) of proton beams is currently assumed to be 1.1. However, there is increasing evidence that RBE increases towards the end of proton beam range that may increase the biological effect of proton beam in the distal regions of the dose deposition. Methods: A computational approach is presented for estimating the biologica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Frontiers in Oncology

سال: 2015

ISSN: 2234-943X

DOI: 10.3389/fonc.2015.00281