Fast dose optimization for rotating shield brachytherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment plan optimization for rotating-shield brachytherapy

In this thesis, we aim to develop fundamentally new techniques and algorithms for efficiently computing rotating-shield brachytherapy (RSBT) treatment plans. We propose that these algorithms will pave the way for making RSBT available in clinical practices. RSBT is an intensity modulated high-dose-rate brachytherapy (HDR-BT) technique. Theoretically, RSBT offers advantages over the conventional...

متن کامل

Rotating-shield brachytherapy (RSBT) for cervical cancer

ii ACKNOWLEDGEMENTS I would like to give my sincere thanks to all who help me to finish this thesis: To Ryan Flynn for his direction, patience and the great support throughout my master study. To Yusung Kim for his generous help on the clinical knowledge and suggestions on my manuscript. To Xiaodong Wu for his instructions on the algorithms to lead our research to go deeper. To Yunlong Liu and ...

متن کامل

Interstitial rotating shield brachytherapy for prostate cancer.

PURPOSE To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). METHODS A wire-mounted 62 GBq(153)Gd source is proposed with an encapsulated diameter of 0.59...

متن کامل

A novel perineal shield for low-dose-rate prostate brachytherapy

PURPOSE To study the impact on radiation exposure to staff through the use of an original perineal shield during low-dose-rate prostate brachytherapy. MATERIAL AND METHODS We designed a 1 mm thick stainless steel shield that duplicates and is able to slide directly over a standard commercialized prostate brachytherapy grid. We then analyzed the post-procedure exposure in 15 consecutive patien...

متن کامل

Global convergence analysis of fast multiobjective gradient-based dose optimization algorithms for high-dose-rate brachytherapy.

We consider the problem of the global convergence of gradient-based optimization algorithms for interstitial high-dose-rate (HDR) brachytherapy dose optimization using variance-based objectives. Possible local minima could lead to only sub-optimal solutions. We perform a configuration space analysis using a representative set of the entire non-dominated solution space. A set of three prostate i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medical Physics

سال: 2017

ISSN: 0094-2405,2473-4209

DOI: 10.1002/mp.12486