Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through
نویسندگان
چکیده
منابع مشابه
Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ride through (LVRT) and high voltage ride through (HVRT) capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and s...
متن کاملVoltage Compensation Using UPQC For DFIG Wind Turbine Low - Voltage Ride - Through Solution
This paper describes the problem of voltage sags and swells and its severe impact on sensitive loads and introduces a new solution for doubly fed induction generators to stay connected to the grid during voltage sags. The main idea is to increase the stator voltage to a level that creates the required flux to keep the rotor side converter current below its transient rating. To accomplish this g...
متن کاملLow Voltage Ride through Capability Improvement of Dfig Based Wind Turbine Using Statcom
This paper studies a control strategy to improve low voltage ride through (LVRT) capability of doubly fed induction generator (DFIG)-based wind turbine (WT). This solution is based on the DFIG with Crowbar circuit control and the installation of STATCOM which is connected at the point of common coupling (PCC). The simulation model of WTs with STATCOM is built using the environment MATLAB/Simuli...
متن کاملEfficient low-voltage ride-through nonlinear backstepping control strategy for PMSG-based wind turbine during the grid faults
This paper presents a new nonlinear backstepping controller for a direct-driven permanent magnet synchronous generator-based wind turbine, which is connected to the power system via back-to-back converters. The proposed controller deals with maximum power point tracking (MPPT) in normal condition and enhances the low-voltage ride-through (LVRT) capability in fault conditions. In this method, to...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2014
ISSN: 1996-1073
DOI: 10.3390/en7074140