Fast Beam Choppers for the Electron-Ring Accelerator
نویسندگان
چکیده
منابع مشابه
Continuous Electron Beam Accelerator Facility,
We use local quark-hadron duality to estimate the purely nonperturbative soft contribution to the γ * p → ∆ form factors. Our results are in agreement with existing experimental data. We predict that the ratio G * E (Q 2)/G * M (Q 2) is small for all accessible Q 2 , in contrast to the pQCD expectations that G * E (Q 2) → −G * M (Q 2).
متن کاملExperiments with electron beam modulation at the DUVFEL accelerator
Recently strong modulation of the electron bunch longitudinal phase space was obtained in the DUVFEL accelerator at NSLS [1,2]. The chirped beam energy spectra exhibit a spiky structure with a subpicosecond spike separation. A model based on the longitudinal space-charge effect has been suggested as an explanation of the observed effect [3,10]. For characterization of the structure and comparis...
متن کاملSimulation of the Fast Beam-Ion Instability in the TESLA Electron Damping Ring
The Fast Beam-Ion Instability is considered potentially harmful in electron storage rings with short bunch spacing and high bunch charge, as it is the case in the proposed electron damping ring of the future linear collider TESLA. It arises from interaction between a stored bunch and an ion cloud previously created by all heading bunches during a single pass. To study this e ect and to determin...
متن کاملAtom beam velocity measurements using phase choppers
We describe a new method to measure atom beam velocity in an atom interferometer using phase choppers. Phase choppers are analogous to mechanical chopping discs, but rather than being transmitted or blocked by mechanical choppers, an atom receives different differential phase shifts (e.g. zero or π radians) from phase choppers. Phase choppers yield 0.1% uncertainty measurements of beam velocity...
متن کاملMonte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1969
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1969.4325439