False positives: handling them operationally for automatic pollen monitoring
نویسندگان
چکیده
Abstract This note provides a generic method for handling falsely identified particles (false positive detections) in automatic pollen monitoring systems. The benefits of the are illustrated using data from two different devices (Swisens Poleno and Plair Rapid-E) comparison to reference Hirst-type measurements. Neither climatological nor phenological information introduced filter out false detections: is based only on
منابع مشابه
Handling false positives in the genomic era.
Both procedures used iodinated contrast media, iohexol (Omnipaque 350; GE Healthcare) in this case. The cause of the “floating gel” was an increase in serum density from residual contrast dye still present in the catheter used for the procedures (1 ). Laboratory tests should not be performed, even if the serum is extracted from beneath the gel barrier. The effect of residual dye is unknown, but...
متن کاملAutomatic and Online Pollen Monitoring.
BACKGROUND Pollen are monitored in Europe by a network of about 400 pollen traps, all operated manually. To date, automated pollen monitoring has only been feasible in areas with limited variability in pollen species. There is a need for rapid reporting of airborne pollen as well as for alleviating the workload of manual operation. We report our experience with a fully automated, image recognit...
متن کاملImprobability Filtering for Rejecting False Positives
In this paper we describe a novel approach, called improbability filtering, to rejecting false-positive observations from degrading the tracking performance of an Extended Kalman-Bucy fdter. False-positives, incorrect observations reported with a high confidence, are a form of non-Gaussian white noise and therefore degrade the tracking performance of an Extended Kalman-Bucy Filter. Improbabilit...
متن کاملFalse positives on diagnostic tests for CHD.
acceleration occurs at the time of valve closure, apparently as a result of the narrowing of the orifice in the face of this forward flow. In contrast, aortic valve closure occurs after cessation of forward flow in aortic stenosis,8 and hence no acceleration and no resulting augmentation of the murmur would be expected. Although the editorial raised a number of other points, with which we disag...
متن کاملFalse positives in cancer epidemiology.
BACKGROUND A recent attempt to estimate the false-positive rate for cancer epidemiology studies is based on agents in International Agency for Research on Cancer (IARC) category 3 (agent not classifiable as to its carcinogenicity to humans) in the IARC Monographs Program. METHODS The estimation method is critiqued regarding biases caused by its reliance on the IARC classification criteria for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Aerobiologia
سال: 2022
ISSN: ['0393-5965', '1573-3025']
DOI: https://doi.org/10.1007/s10453-022-09757-4