False-negative cryptococcal antigen test due to the postzone phenomenon
نویسندگان
چکیده
منابع مشابه
False negative hepatitis B surface antigen detection in dialysis patients due to excess surface antigen: postzone phenomenon.
Renal dialysis patients are well known to have a high incidence of hepatitis B carrier state. In studying a group of 63 long-term dialysis patients, 10 were found to be positive for hepatitis B surface antigen by radioimmunoassay (RIA). Surprisingly, however, only three of these RIA positive patients were positive by counter immunoelectrophoresis (CIEP). The discrepancy could not be accounted f...
متن کاملNew cause for false-positive results with the cryptococcal antigen test by latex agglutination.
The highly specific and sensitive latex agglutination test for cryptococcal antigen detection in cerebrospinal fluid is routine in many hospitals. Contamination of cerebrospinal fluid by a minute amount of syneresis fluid (surface condensation) from agar gave a strongly positive reaction which was heat stable, was not eliminated by pronase treatment, and was not detected by the normal rabbit gl...
متن کاملFalse Negative Fecal Occult Blood Test: Prozone Effect
Dear editor, the fecal occult blood test is the presently widely used screening laboratory test for colorectal cancer. At present, the test is usually based on an immunological diagnostic principle (1, 2). A false positive fecal occult blood is common and widely mentioned in literature. Nevertheless, the false negative is little mentioned in the paper. Here, the authors discuss the issue of the...
متن کاملFalse-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.
متن کاملFalse positive latex tests for cryptococcal antigen in cerebrospinal fluid.
on the instrument, its date, its inventor Lee or the manufacturing or supplying firm ofAL Hawkins Ltd, London. Another machine "The Sedigraph" made by a Swiss firm after the Second World War acted in a similar fashion with rather more sophistication. One of these instruments is also in the collection. The collection of old instruments nlow numbers about 1000 items which, it is hoped, will form ...