Failure To Pace: Pacemaker Malfunction?

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Triboelectric simulation of pacemaker malfunction.

We report the occurrence of a triboelectric phenomenon (static electricity) that mimicked malfunction of a contemporary pacemaker by creating an electrocardiograpic artifact virtually identical to the pacemaker stimuli. The diagnosis was established by observing a subtle overshoot of the questionable deflection that was absent from pacemaker stimuli.

متن کامل

Muscle potentials simulating pacemaker malfunction.

Interference spikes were noted on the electrocardiogram of a patient with an implanted demand pacemaker. Runaway malfunction was suspected and the generator replaced. Subsequent investigation showec that the interference originated from fasciculation in the left leg caused by underlying neuromuscular disease. Skeletal muscle potentials can produce an electrocardiographic appearance closely rese...

متن کامل

Increasing PACE of PACEMAKER Imaging!

Methods A total of 157 patients were imaged on a GE CV/i Excite Version 12, 1.5 T system (GE, Milwaukee, WI). 31 patients had an AICD, 13 patients had an AICD/Pacemaker, 6 patients had a single pacemaker lead, 14 REVO pacemakers and 93 patients had a complete pacemaker implantation. A specific criteria was followed for all the patients undergoing this procedure to scrutinize if the final diagno...

متن کامل

Concealed malfunction of the temporary pacemaker

SS Bollapragada,a JD Norrie,b JE Normana a Division of Developmental Medicine, Maternal and Reproductive Medicine, University of Glasgow, Glasgow Royal Infirmary, Glasgow, UK bCentre for Healthcare Randomised Trials (CHaRT), Health Services Research Unit, Aberdeen University, Aberdeen, UK Correspondence: Dr SS Bollapragada, Division of Developmental Medicine, Maternal and Reproductive Medicine,...

متن کامل

Electrocautery-induced pacemaker malfunction during surgery.

We report a case of electrocautery-induced pacemaker failure that resulted in asystole in a 15-year-old girl scheduled for cardiac surgery. Her pacemaker was converted to the asynchronous mode the night before surgery. Electromagnetic interference from the unipolar electrocautery caused a reduction in the battery voltage, which allowed the digital circuitry, but not the voltage control oscillat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cardiovascular Electrophysiology

سال: 2007

ISSN: 1045-3873,1540-8167

DOI: 10.1111/j.1540-8167.2007.00966.x