Failure pressure analysis of a nuclear reactor prestressed concrete containment building

نویسندگان

چکیده

The failure analysis of an existing and operational nuclear power plant reactor containment building subjected to accident internal pressure is studied in this paper. computation based on the Finite Element Method Serial-Parallel Rule Mixtures. Using these techniques, effect all materials structure considered information for each them obtained as output. mechanism defined through strain thresholds that cannot be exceeded at any point component materials. strains are checked over whole computational process identifying thus critical points. results compared with ones previous work same (Barbat et al., 1998).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Size Effect of Shear Failure in Prestressed Concrete Beams

It is shown that the size effect predicted by dimensional analysis of fracture mechanics of failures due to progressive distributed microcracking agrees with the test data existing in the literature better than the presently used strength (ultimate load) criterion, which exhibits no size effect, and better than the linear i!lastic fracture mechanics criterion, which exhibits much too strong a s...

متن کامل

Prestressed Concrete Piles

A state of the art presentation on prestressed piling as used throughout the world is discussed in this General Report to the FIP Symposium on Mass-Produced Prestressed Precast Elements in Madrid, Spain, May 1968. Historical information, design data and notes along with manufacturing techniques, installation practices, discussion of problems and failures and a complete bibliography are all cove...

متن کامل

Ductility of Prestressed and Partially Prestressed Concrete Beam Sections

D analyses of structures responding elastically to ground motions recorded during severe earthquakes have shown that the theoretical response inertia loads are generally significantly greater than the static design lateral loads recommended by codes. Hence, structures designed for the lateral earthquake loads recommended by codes can only survive severe earthquakes if they have sufficient ducti...

متن کامل

Experiment Site Primary Containment Reactor Pressure Vessel Suppression Pool Building Auxiliary

This article reviews the research program and efforts for the TEXONO Collaboration on neu-trino and astro-particle physics. The " flagship " program is on reactor-based neutrino physics at the Kuo-Sheng (KS) Power Plant in Taiwan. A limit on the neutrino magnetic moment of µ ¯ νe < 1.3 × 10 −10 µ B at 90% confidence level was derived from measurements with a high purity germanium detector. Othe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Engineering Structures

سال: 2021

ISSN: ['0141-0296', '1873-7323']

DOI: https://doi.org/10.1016/j.engstruct.2021.112052