Force and pressure distribution using Macintosh and GlideScope laryngoscopes.
BACKGROUND The forces applied to the soft tissues of the upper airway may have a deleterious effect. This study was designed to evaluate the performance of the GlideScope compared with the Macintosh laryngoscope. METHODS Twenty anaesthetists and 20 trainees attempted tracheal intubation of a Laerdal SimMan manikin. Forces and pressure distribution applied by both laryngoscope blades onto the ...
متن کاملCORRESPONDENCE Force and pressure distribution using Macintosh and GlideScope laryngoscopes
Force and pressure distribution using Macintosh and GlideScope laryngoscopes Editor—Carassiti and colleagues are to be commended for their work attempting to compare the forces applied to the airway during laryngoscopy with the Glidescope Cobalt and the Macintosh laryngoscope. However, one issue deserves comment, there is an important difference between the two blades that was not accounted for...
متن کاملComparing anaesthesiologist's muscular activity and workload during GlideScope vs Macintosh laryngoscopy. Is it really comparable?
1 Jaber S, Chanques G, Jung B. Postoperative noninvasive ventilation. Anesthesiology 2010; 112: 453–6 2 SquadroneV, Coha M, CeruttiE, et al. Continuouspositive airway pressure for treatment of postoperative hypoxemia: a randomized controlled trial. JAMA 2005; 293: 589–95 3 Aguilo R, Togores B, Pons S, Rubi M, Barbe F, Agusti AG. Noninvasive ventilatory support after lung resectional surgery. Ch...
متن کاملComparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics
BACKGROUND Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of t...
متن کاملIncidence and severity of postoperative sore throat: a randomized comparison of Glidescope with Macintosh laryngoscope
BACKGROUND Postoperative sore throat (POST) is a common problem following endotracheal (ET) intubation during general anesthesia. The objective was to compare the incidence and severity of POST during routine intubation with Glidescope (GL) and Macintosh laryngoscope (MCL). METHODS One hundred forty adult patients ASA I and II with normal airway, scheduled to undergo elective surgery under GA...