Failure of Emperion modular femoral stem with implant analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of Emperion modular femoral stem with implant analysis

Modularity in total hip arthroplasty provides multiple benefits to the surgeon in restoring the appropriate alignment and position to a previously damaged hip joint. The vast majority of modern implants incorporate modularity into their design with some implants having multiple modular interfaces. There is the potential for failure at modular junctions because of fretting and crevice corrosion ...

متن کامل

Fatigue fracture of a cemented Omnifit CoCr femoral stem: implant and failure analysis

A cemented, cast CoCr alloy, Omnifit Plus femoral stem was retrieved following mid-stem fracture after 24 years in vivo. The patient was an active 55-year-old male with a high body mass index (31.3) and no traumatic incidents before stem fracture. Fractographic and fatigue-based failure analyses were performed to illuminate the etiology of fracture and retrospectively predict the device lifetim...

متن کامل

Fracture of Revision Modular Femoral Stem

The number of revision total hip arthroplasties is predicted to more than double in USA over the next 25 years from an estimated 40800 in 2005 to approximately 96700 in 2030 [1]. Modular femoral stems offer the advantage of adjustment and restoration of joint kinematics including leg length, femoral version and offset, regardless of the exact position of the distal part of the stem [2]. Disadva...

متن کامل

Periprosthetic femoral fractures treated with a modular distally cemented stem.

PURPOSE To assess the treatment outcome of revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures using a modular distally cemented stem. METHODS 22 men and 14 women (37 hips) aged 66 to 79 (mean, 70) years underwent revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures. The indication for surgery was periprosthetic fracture with stem loose...

متن کامل

Failure of a modular hip implant at the stem-sleeve interface.

In the current era of total hip arthroplasty (THA), orthopedic surgeons have several fixation options at their disposal. The modern monoblock prosthesis, introduced by Dr. Sir John Charnley, has seen many modifications since its inception in the 1970s and continues to be the most commonly used prosthesis style for primary and revision THA. Proximal modular sleeve technology was introduced in 19...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Arthroplasty Today

سال: 2016

ISSN: 2352-3441

DOI: 10.1016/j.artd.2015.11.004