Failure analysis for tube bundle of methanol condensation recovery heat exchanger

نویسندگان

چکیده

The S30408 tube bundle of methanol condensation recovery heat exchanger in a chemical company was found leaked during use. cause leakage analyzed by means macroscopic inspection, composition analysis, metallographic hardness test and fracture analysis. results show that formic acid chloride condensate are formed the exhaust gas shell side near outlet side, which spot corrosion stress cracking tubes. Surface coating or replaced material is recommended to prevent such failure.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twisted Tube Heat Exchanger Technology

Over 85% of all new heat exchanger applications in oil refining, chemical, petro-chemical, and power generation are accommodated through the use of conventional shell and tube type heat exchangers. The fundamental basis for this statistic is shell and tube technology is a cost effective, proven solution for a wide variety of heat transfer requirements. However, there are limitations associated ...

متن کامل

Investigation of Heat Transfer Coefficient Enhancement for CuO/TiO2 Nanocomposite in a Tube Heat Exchanger

In order to improve the efficiency and rate of heat transfer in heat exchangers, various techniques such as increasing the heat transfer coefficient are proposed. This study is devoted to the investigation of heat transfer coefficient variations due to the addition of CuO, TiO2 and CuO/TiO2 nanoparticles into a shell and tube heat exchanger. CuO/TiO2 nanocomposite was synthesized using mechanic...

متن کامل

Effect of baffle oientation on shell tube heat exchanger performance

In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...

متن کامل

Study on Condensation in the Presence of Noncondensables on a Shell - Tube Heat Exchanger

Q. s. Yuan Electricite de France centre des Renardieres Departement Application de l'Electricite 77250 Moret sur Laing, France Noncondensable gases in a condenser will reduce the heat transfer coefficient and this is the case of the mixture (steam + air) j Rll4 heat exchanger in our high temperature heat pump. This heat exchanger is a shell tube type and is for the purpose of simulating industr...

متن کامل

Longitudinal Conduction in Cross Flow Heat Exchanger with Condensation

The deterioration of the performance of a cross flow heat exchanger with condensation due to the longitudinal conduction was investigated. For a relatively small change of wall temperature along the flow directions which was shown to be common in many applications, the energy equations were solved numerically. An iterative method was used to solve the resulting equations of the finite differenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2021

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202126702033