Factors affecting intraosseous pressure measurement
نویسندگان
چکیده
منابع مشابه
Factors affecting intradiscal pressure measurement during in vitro biomechanical tests
OBJECTIVES To assess the reliability of intradiscal pressure measurement during in vitro biomechanical testing. In particular, the variability of measurements will be assessed for repeated measures by considering the effect of specimens and of freezing/thawing cycles. METHODS Thirty-six functional units from 8 porcine spines (S1: T7-T8, S2: T9-T10, S3: T12-T11, S4: T14-T13, S5: L1-L2 and S6: ...
متن کاملFactors Affecting Vehicle Occupancy Measurement
Factors affecting vehicle occupancy measurement were examined with the aim of improving state vehicle occupancy monitoring programs. A comparison was conducted of five data sets looking at the effects on average vehicle occupancy (AVO) of time of day, day of week, road types, HOV lanes, locational differences, and traffic volume. It was found that AVO was higher in the afternoons, on Saturdays,...
متن کاملResearch on Factors Affecting Concrete Cover Measurement
Concrete cover is the distance from the surface of the concrete to the surface of the reinforcing bars embedded in the concrete. Ensuring sufficient concrete cover is critical for the durability of some concrete structures subject to poor environment during their service life. Concrete cover can be measured using covermeters. In this paper, some factors affecting cover measurement were briefly ...
متن کاملFactors affecting measurement of urinary oxalate.
Using a gas-chromatographic method, we examined the effects of phosphate concentration, added calcium chloride, and pH on precipitation of oxalate from urine. All three factors are important, but the pH of precipitation is particularly so, especially in the presence of even normal concentrations of ascorbic acid. At pH 8, increases in measured oxalate ranged from 20% at an ascorbic acid concent...
متن کاملFactors Affecting Ambulatory Blood Pressure Reproducibility
To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Orthopaedic Surgery and Research
سال: 2018
ISSN: 1749-799X
DOI: 10.1186/s13018-018-0877-z