Factor VIII inhibitor assay using skin puncture blood samples.
نویسندگان
چکیده
منابع مشابه
FACTOR V AND VIII INHIBITOR IN PATIENTS WITH COMBINED FACTOR V AND VIII DEFICIENCY
Patients with coagulation factor(s) deficiency who use coagulation therapy are susceptible to forming inhibitors against coagulation factor(s). In this survey we detected factor V and VIII inhibitor in ten patients with combined deficiency of factors V and VIII from north east of Iran (Khorassan province). It was revealed in our survey that eight patients had both factor V and factor VIII i...
متن کاملAcquired factor VIII inhibitor.
PERSISTENT or uncontrolled bleeding is one of the most feared consequences of any surgical procedure. Numerous factors can contribute to its etiology. Among these, both inherited and acquired disorders of coagulation and/or thrombocyte function need to be taken into account. Acquired hemophilia can be caused by antibodies to coagulation factors. Antibodies can arise in hemophilic or nonhemophil...
متن کاملfactor v and viii inhibitor in patients with combined factor v and viii deficiency
patients with coagulation factor(s) deficiency who use coagulation therapy are susceptible to forming inhibitors against coagulation factor(s). in this survey we detected factor v and viii inhibitor in ten patients with combined deficiency of factors v and viii from north east of iran (khorassan province). it was revealed in our survey that eight patients had both factor v and factor viii inhib...
متن کاملSuccessful elimination of factor VIII inhibitor using cyclosporin A.
Acquired Factor VIII (FVIII) deficiency is an uncommon but sometimes catastrophic autoimmune condition for which standard immune suppression, such as steroid or immunoglobulin infusion, is often insufficient to induce long-term remission (Dykes et al, 2001). A number of second-line therapies, such as cyclophosphamide, azathioprine and vincristine, have been used with varying success (Morrison &...
متن کاملComparison of blood glucose measurements using samples obtained from the forearm, finger skin puncture, and venous serum.
BACKGROUND Blood glucose testing (BGT) at the forearm minimizes the pain experienced during sampling of capillary blood. We compared the BGT results for forearm sampling with those for standard finger skin puncture and venous serum to evaluate the clinical validity of forearm BGT. METHODS BGT was performed on the finger (G(F)) and forearm (G(A)) with a portable glucometer in 555 subjects, inc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Pathology
سال: 1990
ISSN: 0021-9746
DOI: 10.1136/jcp.43.5.433