Fabrication of Solid Contact Ion Selective Electrode for Mercury (II) Using Conductive Polymer Membrane
نویسندگان
چکیده
منابع مشابه
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملA Solid-Contact Ion Selective Electrode for Copper(II) Using a Succinimide Derivative as Ionophore
All-solid-state sensors with polyvinyl chloride (PVC)-based membranes using off-the-shelf N-hydroxysuccinimide (NHS) and succinimide (Succ) ionophores were prepared using DOP (dioctyl phthalate) and NPOE (ortho-nitrophenyloctyl ether) as plasticizers. Good responses were obtained when NHS was used. The potentiometric response of the proposed electrode is independent of pH over the range 2-6. Th...
متن کاملSolid-Contact Reference Electrode for Ion-Selective Sensors
This work presents a flexible miniaturized ion-selective sensor consisting of a solidcontact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. Th...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملCu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATERIALS TRANSACTIONS
سال: 2015
ISSN: 1345-9678,1347-5320
DOI: 10.2320/matertrans.ma201562