Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects ofHp(3) monitoring. A 2015 review

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of H p (3) monitoring. A 2015 review.

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the fol...

متن کامل

Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters†.

The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of -15 % vs. TLD. Tests carried out with other...

متن کامل

Practical Aspects of Radiation Protection in Interventional Radiology

The rise in the frequency of interventional procedures over recent years is due to the significant benefits of interventional radiology. Patients may be treated as an out-patient for clinical conditions, which would have otherwise needed surgery, i.e., a more traumatic and expensive treatment. In some circumstances, for example in neuroradiology the aneurysm may be inoperable surgically and int...

متن کامل

Status of eye lens radiation dose monitoring in European hospitals.

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monito...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Radiological Protection

سال: 2015

ISSN: 0952-4746,1361-6498

DOI: 10.1088/0952-4746/35/3/r17