External Dose Calculation Using Computer Simulation.
نویسندگان
چکیده
منابع مشابه
Calculation of gel dose after external radiation therapy using optical CT
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...
متن کاملCalculation of wedged dose distributions using an analytical method
Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...
متن کاملThe calculation of total dose using SPENVIS
The potential radiation dose for the Solar-B EIS CCDs was discussed in reference [1], and the potential effect of that radiation dose was discussed in reference [2]. Whilst the effect of ionising radiation on CCD areas such as flat band voltage shifts was not a cause for concern (although the transient effects on image quality may be) there was a potential problem with the effect of Non-Ionisin...
متن کاملSimulation of beam record data for 4D dose calculation
Treatment of moving targets can result in local over and under dosage due to interference effects of the beam application and the motion of the target. First experimental studies [1] as well as theoretical works [2, 3] showed that multiple irradiations with an accordingly reduced dose per irradiation reduce these inhomogeneities due to averaging effects. If the multiple irradiations are perform...
متن کاملFast CPU-based Monte Carlo simulation for radiotherapy dose calculation.
Monte-Carlo (MC) simulations are considered to be the most accurate method for calculating dose distributions in radiotherapy. Its clinical application, however, still is limited by the long runtimes conventional implementations of MC algorithms require to deliver sufficiently accurate results on high resolution imaging data. In order to overcome this obstacle we developed the software-package ...