Extent-based kinetic identification using spectroscopic measurements and multivariate calibration
نویسندگان
چکیده
منابع مشابه
Extent-based kinetic identification using spectroscopic measurements and multivariate calibration.
Extent-based kinetic identification is a kinetic modeling technique that uses concentration measurements to compute extents and identify reaction kinetics by the integral method of parameter estimation. This article considers the case where spectroscopic data are used together with a calibration model to predict concentrations. The calibration set is assumed to be constructed from reacting data...
متن کاملGaussian Process Regression for Multivariate Spectroscopic Calibration
Traditionally multivariate calibration models have been developed using regression based techniques including principal component regression and partial least squares and their non-linear counterparts. This paper proposes the application of Gaussian process regression as an alternative method for the development of a calibration model. By formulating the regression problem in a probabilistic fr...
متن کاملExtent-based incremental identification of reaction systems using concentration and calorimetric measurements
Extent-based incremental identification uses the concept of extents and the integral method of parameter estimation to identify reaction kinetics from concentration measurements. The approach is rather general and can be applied to open both homogeneous and gas–liquid reaction systems. This study proposes to incorporate calorimetric measurements into the extent-based identification approach for...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytica Chimica Acta
سال: 2013
ISSN: 0003-2670
DOI: 10.1016/j.aca.2012.12.032