Mist spraying is a technique for locally lowering air temperature by fine mist into the and using latent heat of evaporation immediately after spraying. This study focuses on conditions under which contributes to increase in sensible release from human body, ratio decrease humidity space where sprayed. From measurement results front air-conditioning condenser unit, increased about 10 g/kg(DA), while decreased °C. an open park, 0.5 1 °C within 2 m spray g/kg(DA) at height spray, regardless distance spray. semi-open bus stops, slightly low-wind conditions. Unfortunately, measured relation increase, body perceives as cooler, were not available.
منابع مشابه
Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners
In this paper,
 the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby pre...
متن کاملEffect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners
In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...
متن کاملapplication of open cooling tower with radiant cooling for office space conditioning in temperate climate
0
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کامل: the effect of sericin levels (silk glue protein) on rate of in vitro maturation, fertilization and culture of sheep oocytes
هدف از آزمایش اول بررسی اثر سطوح مختلف سریسین [0 (control), 0.1, 0.5, 1.0, 2.5 %] افزوده شده به محیط , ivm بر cumulus cell expansion، بلوغ هسته و توسعه متوالی جنین، در گوسفندان نژاد سنجابی در فصل تولید مثلی می باشد. از سرگیری میوز به وسیله خارج شدن اولین پولار بادی اندازه گیری و هم چنین درصد رسیدن جنین های دو سلولی به مرحله کلیواژ و بلاستوسیت نیز به عنوان نشانه ای از میزان شایستگی توسعه اولیه ج...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atmosphere
سال: 2023
ISSN: ['2073-4433']
DOI: https://doi.org/10.3390/atmos14010177