Experimental Validation of Color Doppler Velocity Measurement for Ultrasonic-Measurement-Integrated Simulation of Blood Flow

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

Transcranial Doppler measurement of middle cerebral artery blood flow velocity: a validation study.

Measurement of intracranial arterial blood flow velocity is a new technique with potentially a number of very useful applications. This study validates the technique by comparing it to cerebral blood flow (CBF) measured using intravenous Xenon133 and extracranial clearance recording. We have measured the middle cerebral artery (MCA) blood flow velocity in 17 symptomatic patients with the EME TC...

متن کامل

Transthoracic Doppler echocardiographic measurement of left atrial appendage blood flow velocity: comparison with transoesophageal measurement.

AIM We validated transthoracic echocardiographic measurements of left atrial appendage flow velocity by comparing them with transoesophageal echocardiographic measurements. METHODS AND RESULTS Eighty-four consecutive patients (mean age, 64.6 years) with various cardiac diseases, who underwent both transthoracic echocardiography and transoesophageal echocardiography were studied. Thirty-two pa...

متن کامل

Ultrasonic Flow Measurement with Integrated Temperature Measurement Compensation

Compensation for ultrasonic flow measurement has increasingly become the trend for applications that call for higher accuracy and tighter repeatability. Temperature is a variable that tends to have a significant impact on performance. Geometric dimension changes due to thermal expansion and contraction, as well as fluid dynamics, are impacted by temperature and thus have an influence on overall...

متن کامل

Ultrasonic blood flow measurement in haemodialysis.

A 5-megacycle Doppler flow meter, calibrated in-vitro, was found to give a linear response to blood flow in the ranges commonly encountered in haemodialysis. With this, blood flow through artificial kidneys could be measured simply and with a clinically acceptable error. The method is safe, as blood lines do not have to be punctured or disconnected and hence there is no risk of introducing infe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Biomechanical Science and Engineering

سال: 2008

ISSN: 1880-9863

DOI: 10.1299/jbse.3.161