Push Over Analysis of Unstiffened Steel Plate Shear Wall

Steel Plate Shear Wall (SPSW) is made from thin steel plate which in turn are framed by the beams and columns of structural system. In recent year they are proved to be very effective and economical for resisting lateral loads such as earthquake and wind loads.The present work targets to study the behaviour of single frame SPSW with different plate thicknesses, rigid and non-rigid frame members...

متن کامل

Design of Unstiffened Extended Single-Plate Shear Connections

Extended single-plate shear connections (Figure 1) offer many advantages that simplify the construction process. Because the connection to the supported member is moved clear of the support, coping of the supported member is not required and the only fabrication process required for the supported member is drilling or punching. Also, because bolted connections are only used in the connection to...

متن کامل

Experimental Study and Comparative Numerical Analysis of the Mechanical Behavior of Extended End-Plate Connections with End-Plate Stiffeners

To investigate the influence of end-plate stiffeners on the initial rotational stiffness of extended end-plate internal joints, an experimental program was carried out to investigate the rotational behavior of the joints. Two finite element methods (FEMs) were proposed using ABAQUS software. The stress distribution, plastic development, and deformation characteristics of extended end-plate join...

متن کامل

Comparison of nerve repair with end to end, end to side with window and end to side without window methods in lower extremity of rat

  Abstract   Background : Although, different studies on end-to-side nerve repair, results are controversial. The importance of this method in case is unavailability of proximal nerve. In this method, donor nerves also remain intact and without injury. In compare to other classic procedures, end-to-side repair is not much time consuming and needs less dissection. Overall, the previous studies i...

متن کامل

Experimental and Numerical Study of Perforated Steel Plate Shear Panels

Thin perforated Steel Plate Shear (SPS) Walls are among the most common types of energy dissipating systems. The applied holes reduce the shear strength of the plate and allow to decrease the profile size of the members at the boundary of the panel when these systems are used in the typical design of structures. On the other hand, the different fracture locations of these panels are visible whe...