Experimental Study on Seismic Retrofitting for Existing R/C Buildings Using Steel Columns

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrofitting of Existing Rc Square Bridge Columns Using Basalt Frp Rebars

Fiber-reinforced polymers (FRPs) have been widely utilized to improve the seismic performance of deficient reinforced concrete (RC) columns. In recent years, one of the emerging types of FRPs used is basalt fibers. In this study, the performance of existing columns was experimentally examined before and after applying near-surface mounted (NSM) basalt FRP (BFRP) rebars as a retrofitting techniq...

متن کامل

Seismic Vulnerability Assessment of Existing Rc Buildings in Gis Environment

With rapid population growth over the past 30 years and no significance seismic activity during this period, the unchecked development of the built environment in Bangladesh has been resulted in little resilience to earthquake. Identifying buildings due to this unchecked development that has high vulnerability is of critical importance both for reliable loss estimation as a result of an expecte...

متن کامل

Seismic Retrofitting of Existing Shear Walls by Means of High Performance Rc Jacket

A new technique for the strengthening of existing R/C shear walls based on the application of very thin high performance jackets is presented in this paper. The strengthening jacket is made of high performance concrete and high strength steel mesh. The experimental study on a 1:3 scale R/C wall, proportioned to resist the vertical loads only, and reinforced by means of a 15 mm thick high perfor...

متن کامل

An Experimental Study on Non-Compression X-Bracing Systems Using Carbon Fiber Composite Cable for Seismic Strengthening of RC Buildings

Cross-bracing (X-bracing) is one of the most popular methods of seismic retrofitting, and has been shown to significantly increase the structural stiffness and strength of buildings. Conventional steel X-bracing methods typically exhibit brittle failure at the connection between the brace and the building, or buckling failure of the braces. This study investigated the structural properties of a...

متن کامل

The Effect of Analysis Methods on the Response of Steel Dual-System Frame Buildings for Seismic Retrofitting

In the present paper, the focus is on the evaluation of steel dual-system frame buildings using four main types of structural analysis (Linear Static, Linear Dynamic, Nonlinear Static and Nonlinear Dynamic Analyses) with regard to "Seismic Rehabilitation Code for Existing Buildings in Iran" (based on FEMA 273 and 356) where the first two authors of the article tend to follow the previous work (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Concrete Research and Technology

سال: 2014

ISSN: 1340-4733,2186-2745

DOI: 10.3151/crt.25.13