Experimental study on performance of heat pump air conditioning system for pure electric bus with economizer
نویسندگان
چکیده
When the exhaust temperature of heat pump air conditioning system pure electric bus is too high, performance attenuated. In order to solve problem, an alternative with low pressure supply developed. The experimental platform set up reveal main factors affecting refrigeration and heating system. results show that air-supply technology can significantly reduce compressor.
منابع مشابه
Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملDetermining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations
One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...
متن کاملPerformance Analysis of an Integrated Heat Pump with Air-Conditioning System for the Existing Hospital Building Application
In this study, a complete evaluation procedure of energy-saving and efficiency improvement for a large-scale hospital retrofit project has been established and successfully validated in Taiwan. The retrofit scheme, in integrating the alternative hot water system, namely, a water source heat pump (WSHP), with the existing HVAC (Heating, Ventilating, and Air-Conditioning) system, enables the capa...
متن کاملa study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولExperimental Study on Extremum Seeking Control for Efficient Operation of Air-side Economizer
The air-side economizers have been developed as a major class of energy-saving equipment to enhance the energy efficiency of central air-conditioning systems by taking advantage of outdoor air during cool or cold weather. In current practice, the outdoor air damper is controlled to maintain either the maximum or minimum opening by comparing the outdoor air temperature/enthalpy with the setpoint...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thermal Science
سال: 2021
ISSN: ['0354-9836', '2334-7163']
DOI: https://doi.org/10.2298/tsci191228091s