Experimental Study on Hydration Heat Control of Mass Concrete by Vertical Pipe Cooling Method

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation of Heat Transfer Enhancement in a Finned U-Shaped Heat Pipe of CPU Cooling System Using Different Fluids

This paper experimentally studies the heat absorption performance of a heat sink with vertical embedded heat pipes in the aluminum blade. The cooling system with embedded heat pipes distributes heat from the CPU to both the base plate and the heat pipes, and then transfer heat from fins to the Environment. The thermal resistance and heat transfer coefficient are evaluated for natural convection...

متن کامل

Experimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids

This paper presents the experimental investigations conducted on a vertical closed loop pulsating heat pipe (VCLPHP) to evaluate the thermal performance. The values of thermal resistance and heat transfer coefficient obtained in the experimentation is used as evaluation parameters. The VCLPHP used has capillary tubes having an inner diameter of 2mm and outside diameter 3mm and bent into 5 turns...

متن کامل

Experimental Investigation on Thermal Performance of Cooling System Using Thermoelectric Module Integrated with Heat Pipe

ARTICLE INFO Cooling of electronics component is one of the major challenges faced by thermal engineers. In recent years, a significant increase in microprocessor power dissipation coupled with CPU size has resulted in an increase in heat fluxes. Microprocessor heat fluxes have also increased for many commercial applications. Therefore, thermal management is becoming one of most challenging iss...

متن کامل

Experimental Research on the Hydration Heat Temperature Field of Hollow Concrete Piers

Measuring points were observed continuously to reveal the hydration heat temperature distribution of hollow concrete bridge pier. The results showed that as the thickness of the pier increased, the central temperature of the pier increased significantly due to hydration and the heat was difficult to be dissipated. The hydration temperature accounted for up to 70% of the maximum temperature rise...

متن کامل

Energy Conservation Potential of the Heat Pipe Heat Exchangers: Experimental Study and Predictions

The energy conservation potential of the heat pipe based heat exchangers (HPHXs) was studied in this research. To this end, a typical climate chamber as the representative of an air conditioning system was established. The performance characteristic of a typical eight-row HPHX was obtained based on the one week operation (168 h) to determine the performance characteristic curves. The coil face ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Asian Architecture and Building Engineering

سال: 2015

ISSN: 1346-7581,1347-2852

DOI: 10.3130/jaabe.14.657