EXPERIMENTAL STUDY ON ECCENTRICALLY LOADED STIFFENED BOX COLUMNS
نویسندگان
چکیده
منابع مشابه
Experimental and numerical study on the structural behavior of eccentrically loaded GFRP columns
Glass fiber reinforced polymer (GFRP) pultruded profiles are being increasingly used in civil engineering applications. Although they offer several advantages over traditional materials, such as high strength, lightness and non-corrodibility, GFRP profiles present low elasticity and shear moduli, which together with their slender walls makes them very prone to buckling phenomena. Several previo...
متن کاملAmbient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملEccentrically loaded strip foundation on geogrid-reinforced sand
Results are presented for laboratory model tests conducted to determine the ultimate bearing capacity of an eccentrically loaded strip foundation supported by geogridreinforced sand. Only one type of sand at one relative density of compaction and one type of geogrid were used for the tests. The depth of the foundation was varied from zero to B (width of foundation). Based on the laboratory test...
متن کاملExperimental Study of a Square Foundation with Connected and Non-Connected Piled Raft Foundation Under Eccentrically Loaded
In the recent years, non-connected piled raft foundation has been considered as an economical and practical deep foundation in the situation that high shear and concentrated loads may occur at the connection of the raft and pile head. This paper was presented an experimental study of a square foundation on the effects of parameters such as S/D, L/D and etc. in two cases of connected or non-conn...
متن کاملPerformance of Stiffened Slender Built up Steel I-Columns
Abstract—The present work illustrates a parametric study for the effect of stiffeners on the performance of slender built up steel Icolumns. To achieve the desired analysis, finite element technique is used to develop nonlinear three-dimensional models representing the investigated columns. The finite element program (ANSYS 13.0) is used as a calculation tool for the necessary nonlinear analysi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Doboku Gakkai Ronbunshu
سال: 1984
ISSN: 0289-7806,1882-7187
DOI: 10.2208/jscej.1984.350_197