Experimental Study on Damage Identification of Nano-SiO2 Concrete Filled GFRP Tube Column Using Piezoceramic Transducers

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Study on Stress Monitoring of Sand-Filled Steel Tube during Impact Using Piezoceramic Smart Aggregates

The filling of thin-walled steel tubes with quartz sand can help to prevent the premature buckling of the steel tube at a low cost. During an impact, the internal stress of the quartz sand-filled steel tube column is subjected to not only axial force but also lateral confining force, resulting in complicated internal stress. A suitable sensor for monitoring the internal stress of such a structu...

متن کامل

Experimental Study on Performance of Fiber Concrete-filled Tube Columns under Axial Loading

There have been great developments in the area of civil engineering in the recent few decades and among these, construction and material innovation are quite prominent. Steel-concrete composite construction has emerged as one of the fastest methods of construction. Even though considerable research efforts on conventional reinforced concrete columns have been executed prior to now, concrete fil...

متن کامل

Cyclic Evolution of Damage and Beam-column Interaction Strength of Concrete-filled Steel Tube Beam-columns

The assessment of response of composite seismic force resisting systems requires accurate nonlinear formulations for the composite members. In this work, reporting the first phase of a NEES project, a three-dimensional distributed plasticity formulation is presented for both circular and rectangular composite concrete-filled steel tubes (CFTs) that includes new constitutive models for the concr...

متن کامل

Experimental Modal Analysis of a Concrete-filled Tube Arch Bridge

This paper presents the experimental and analytical modal analysis of a concrete-filled (CFT) tube half-through arch bridge, with the span length of 90m, located at the center of Xining City, Qinghai province, China. Dynamic field test was carried out just prior to the official opening of bridge in order to inspect the dynamic characteristics of the bridge and make a baseline record for the fut...

متن کامل

Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube

In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2020

ISSN: 1424-8220

DOI: 10.3390/s20102883