Experimental study of grouted sleeve connections under bending for steel modular buildings
نویسندگان
چکیده
In steel modular buildings, both inter- and intra-module connections can attract bending moment under the action of lateral loads. The is distributed in accordance with relative stiffness ratios among structural components hence should have sufficient flexural resistance to connecting members be classified as a rigid connection. Typically, (beam-column joints within module) are designed full-strength connections, while inter-module normally pin-connected for fast-track construction. This paper proposes use grouted sleeve connection which does not require bolting or welding achieve construction buildings. An experimental programme carried investigate two types shear-keyed versus slot-hole sleeve, loading evaluate their performance terms strength, stiffness, ductility. results showed that adequate ductility resist they partial strength braced analytical model, based on EN1992-1-1, proposed predict purpose design.
منابع مشابه
Experimental study of grouted sleeve lapping connector under tensile load
The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load-displacement curves of the specimens are discussed in the study. Two equations are proposed for ...
متن کاملShear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading
In this study, two short precast concrete columns and two cast-in-situ concrete columns were tested under cyclic loads. It was shown that the sleeve grouted connection was equivalent to the cast-in-situ connections for short columns when the axial compression ratio was 0.6. In order to determine the influence of the axial compression ratio and the shear-span ratio on the shear capacity of the h...
متن کاملExperimental Study for Strength Capacity of Cold-Formed Steel Joists Connections with Consideration of Various Bolts Arrangements
With growth the construction technologies, Cold-Formed Steel, CFS, sections are widely used in ordinary steel buildings because of some advantages such as light weight, ease of installation, decrease in cost, and increase in speed of operation. Using the bolted connections for CFS joist is one of the best details for steel structures. The main objective of this study is to conduct an experiment...
متن کاملComputational and Experimental Mechanical Modelling of a Composite Grouted Splice Sleeve Connector System
Owing to its controllable tolerance, simple operation and no need for welding at construction site, the composite system involving grouted cement material, steel material and ductile iron material is widely used as grouted splice sleeve (GSS) connector for connecting precast concrete structures. However, the current design recommendations for such a composite connection system do not accurately...
متن کاملEffect of sleeve length on deformation properties of grouted splices
Tests on 12 grouted splices were performed to investigate their deformation properties under tensile loading. Test variables included diameter and type of spliced bars and the size of splicing sleeves. Finite element method based models of the splices were built, verified and used to investigate the effect of sleeve length on the deformation properties of the grouted splices. The sleeve length ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2021
ISSN: ['0141-0296', '1873-7323']
DOI: https://doi.org/10.1016/j.engstruct.2021.112614