Experimental Study of Energy Dissipation at Baffled Chute Spillway
نویسندگان
چکیده
منابع مشابه
Experimental Study of the Effect of Gabion Structure on the Energy Dissipation of Submerged Hydraulic Jump Downstream of Ogee Spillway
In the last decade, the use of gabion structures in hydraulic engineering for stabilizing the structure due to its high density and weight has become widespread. Also, the material's roughness and porosity cause it to be used in energy dissipation and drainage projects. This study evaluates the relative energy dissipation of gabion structures downstream of the ogee spillway in the conditions of...
متن کاملEffects of End Sill and Step Slope on Stepped Spillway Energy Dissipation
In this study, experimental procedure and laboratory works have been conducted to investigate the energy loss rate on stepped spillway, using inclined steps together with end sill. To have a more elucidated investigation inclined steps with different slopes (Horizontal , 7, 10, and 12 degrees with respect to the horizon) and end sill with different thicknesses (5 and 10 mm) and heights (6, 8, 1...
متن کاملExperimental study on energy dissipation of electrolytes in nanopores.
When a nonwetting fluid is forced to infiltrate a hydrophobic nanoporous solid, the external mechanical work is partially dissipated into thermal energy and partially converted to the liquid-solid interface energy to increase its enthalpy, resulting in a system with a superior energy absorption performance. To clarify the energy dissipation and conversion mechanisms, experimental infiltration a...
متن کاملInfluence of Slope and the Number of Steps on Energy Dissipation in Stepped Spillway Using Numerical Model
Recently the stepped spillways have been used as an appropriate solution for energy dissipation. In the present study, Siahbisheh dam spillway is simulated by using Computational Fluid Dynamic (CFD), in which the Mixture method and Reynolds Stresses Model (RSM) turbulence model is used. In the first modeling series the over all steppes slope is constant. The number of the steps is increased to ...
متن کاملEnergy Dissipation down a Stepped Spillway with Non- Uniform Step Heights
While most stepped spillway design guidelines were developed for uniform step heights, a nonuniform stepped design might be a practical alternative in some cases. A physical study was conducted in a moderate slope stepped chute (1V:2H) and five stepped configurations were tested for 0.7 < dc/h < 1.9. Detailed air-water flow measurements were performed for each configuration and the results were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Teknik Sipil
سال: 2019
ISSN: 2549-2659,0853-2982