Experimental study of a sustainable cooling process hybridizing indirect evaporative cooling and mechanical vapor compression
نویسندگان
چکیده
The hybrid indirect evaporative cooling-mechanical vapor compression (IEC-MVC) process is an emerging cooling technology that combines the advantages of IEC and MVC, i.e., effective temperature humidity control, high energy efficiency, low water consumption. This paper presents experimental study IEC-MVC process. A 1-Rton pilot fabricated by connecting MVC in series, its performance evaluated under different operating conditions (outdoor air humidity, flowrate, compressor frequency). Results revealed outdoor could be lowered to 5–15 °C 5–10 g/kg, respectively. handles 35%–50% total load, consumption can reduced 15%–35% as compared standalone MVC. Moreover, condensate collected from evaporator compensate for >70% IEC, making system applicable arid regions. Based on derived results, a simplified empirical model developed rapid evaluation process, energy-saving potential major cities Saudi Arabia estimated.
منابع مشابه
Steam compression with inner evaporative spray cooling: a case study
An adiabatic dry saturated steam compression process with inner evaporative spray cooling in screw compressors for steam heat pump systems is studied. Thermodynamic model and simulation of this variable-mass compression process are devised. Differential equations are formulated and used to calculate the amount of liquid injected and the work to drive the compressor on the basis of simplificatio...
متن کاملEvaporative cooling of sodium atoms.
s (to be published) Abstract No. 1-M3. [9] W. Petrich, M. H. Anderson, J. R. Ensher, and E. A. Cornell, in Fourteenth International Conference on Atomic Physics, Boulder Colorado, 1994 (Ref. [8]). [10] M. Kasevich (private communication). [11] E. Tiesinga, A. J. Moerdijk, B. J. Verhaar, and H. T. C. Stoof, Phys. Rev. A 46, R1167 (1992). [12] H. F. Hess, Phys. Rev. B 34, 3476 (1986). [13] K. B. ...
متن کاملSimulation of Radiant Cooling Performance with Evaporative Cooling Sources
This project addresses three closely related and similarly complex questions: First, using currently available simulation software, what methods might be appropriate for comparing slabintegrated radiant cooling to more conventional alternatives, such that the results are sufficiently fair and comprehensive to support system selection and design? Second, what is the relative performance of repre...
متن کاملIntra-arrest transnasal evaporative cooling: a randomized, prehospital, multicenter study (PRINCE: Pre-ROSC IntraNasal Cooling Effectiveness).
BACKGROUND Transnasal evaporative cooling has sufficient heat transfer capacity for effective intra-arrest cooling and improves survival in swine. The aim of this study was to determine the safety, feasibility, and cooling efficacy of prehospital transnasal cooling in humans and to explore its effects on neurologically intact survival to hospital discharge. METHODS AND RESULTS Witnessed cardi...
متن کاملAutomated Fault Detection and Diagnostics for Vapor Compression Cooling Equipment
Automated fault detection and diagnostic (FDD) systems have the potential to reduce equipment downtime, service costs, and utility costs. However, very few commercial products exist and the ones that do exist are very specialized. This may be surprising to some, considering that FDD is very well developed for other applications such as for nuclear power plants, aircraft, chemical process plants...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Reports
سال: 2022
ISSN: ['2352-4847']
DOI: https://doi.org/10.1016/j.egyr.2022.06.019