Experimental Research on Relationship between UHF Partial Discharge Signals and Discharge Quantity in GIS

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uhf and Acoustic Partial Discharge Localisation in Power Transformers

The reliability of electrical energy networks depends on the quality and availability of electrical equipment like power transformers. Local failures inside their insulation may lead to catastrophic breakdowns and can cause high outage and penalty costs. Beside the strength and type of a PD, the geometric PD position is of major interest concerning risk evaluation of the flaw. Conventional PD m...

متن کامل

Partial Discharge Diagnosis on GIS Based on Envelope Detection

In order to detect and identify the defects on GIS, the ultra-high frequency envelope detection circuit and high-speed data acquisition system was designed, and the tests of five typical defects for GIS were made in the laboratory and the envelope signal was acquired based on Ultra-high frequency (UHF) envelop detection circuit. And wavelet denoising technique was used to reduce the white noise...

متن کامل

Partial Discharge Monitoring of Power Transformers by UHF Sensors

The reliability of electrical energy networks depends on both, the quality and the reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation can lead to breakdowns and hence to high outage and penalty costs. Usually, power transformers are tested on partial discharge (PD) activity before commissioning. UHF PD monitoring can be used to prevent these...

متن کامل

Characteristic Analysis of Partial Discharge Detection in GIS

Abstract Partial discharge (PD) detection is a valuable method for the estimation of GIS condition, and the PD mapping is benefit for GIS defects identification. To investigate the PD characteristic of the GIS model, this paper simulates different PD maps of various fault simulations, and the characteristics of PD map is acquired by the pulse amplitude, phase and the discharge density to identi...

متن کامل

Self-Adaptive Morphological Filter for Noise Reduction of Partial Discharge Signals

Partial Discharge assessment in the insulation of high voltage equipment is one of the most popular approaches for prevention of the insulation breakdown. In the procedure of thisassessment, noise reduction of partial discharge signals to get the original PD signal for accurate evaluation is inevitable. This denoising process shall be carried out such a way that the main features of the p...