Experimental Performance Evaluation of MR Damper for Integrated Isolation Mount
نویسندگان
چکیده
منابع مشابه
OPTIMAL HYBRID BASE ISOLATION AND MR DAMPER
In this paper, optimal design of hybrid low damping base isolation and magnetorheological (MR) damper has been studied. Optimal hybrid base isolation system has been designed to minimize the maximum base drift of low damping base isolation system where for solving the optimization problem, genetic algorithm (GA) has been used. In design procedure the maximum acceleration of the structure has ...
متن کاملDesign, Fabrication and Evaluation of MR Damper
This paper presents the design, fabrication and evaluation of magneto-rheological damper. Semi-active control devices have received significant attention in recent years because they offer the adaptability of active control devices without requiring the associated large power sources. Magneto-Rheological (MR) dampers are semiactive control devices that use MR fluids to produce controllable damp...
متن کاملEffects of Mathematical Model of MR Damper on Its Control Performance; A Nonlinear Comparative Study
In this paper, the effect of mathematical representation method of an MR damper on the performance of control algorithm is investigated. The most exact and common Maxwel Nonlinear Slider (MNS) and modified Bouc-Wen hysteretic models are employed through a nonlinear comparatve numerical study. In many of semi-active control algorithms, a mathematical modelling method is required for determinig ...
متن کاملVibration Control of MR Damper Landing Gear
In the field of Automation, Fuzzy Control Fuzzy control has significant merits which are utilized in intelligent controllers, especially for vibration control systems. This paper is concerned with the application aspects of the developed MR damper for landing gear system, to attenuate the sustained vibrations during the landing phase. Also a comparative study is made on the responses obtained f...
متن کاملSeismic Response Reduction of a Building Using Top-Story Isolation System with MR Damper
In this study, the adaptability of a semi-active top-story isolation system with an MR damper for reduction of seismic responses of tall buildings has been investigated. To this end, a 20-story building structure was selected as an example. Low damping elastomeric bearings and an MR damper were used to compose a smart top-story isolation system. Artificial earthquakes generated based on design ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Korean Society for Noise and Vibration Engineering
سال: 2010
ISSN: 1598-2785
DOI: 10.5050/ksnve.2010.20.12.1161