Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers
نویسندگان
چکیده
منابع مشابه
Numerical Modeling of Slinky-coil Horizontal Ground Heat Exchangers Considering Snow Coverage Effects
The number of Slinky-coil horizontal ground heat exchangers (HGHEs) has been increasing in geothermal heat pump (GHP) systems due to the low initial cost. The performance of the Slinky-coils, however, has not been successfully predicted with good accuracy since the complicated shape of the Slinky-coils is not easy to model either analytically or numerically. To enable this, Fujii et al. (2012) ...
متن کاملnumerical simulation of a horizontal ground-coupled heat pump
this study represents effect of four variables in performance of a heat-pump in two cities of tehran and rasht. a computer program has been developed, simulating a certain heat pump acting in different environments with different refrigerants in heating season. the analysis is based on a homogeneous model. effect of different refrigerants, depth of the buried heat exchangers and moisture conten...
متن کاملHeat Transfer Modeling of the Ground Heat Exchangers for the Ground-Coupled Heat Pump Systems
Ground-coupled heat pump (GCHP) systems have been gaining increasing popularity for space air conditioning in buildings due to their reduced energy and maintenance costs. The efficiency of GCHP systems is inherently higher than that of the traditional options because it utilizes the ground which maintains a relatively stable temperature all the year round as a heat source/sink. Compared with tr...
متن کاملPerformance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System
This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...
متن کاملThe Effect Of Seasonal Variation On Thermal Performance Of Horizontal Slinky-Loop Ground Heat Exchanger
For ground-source heat pump (GSHP) installations, it is important to predict the thermal performance and economic feasibility prior to the introduction of the system. Numerical modelling can be used as an analytical method to accurately predict the thermal performance of such system. It is desirable that the modelling to incorporate seasonal variation during long period of operation, which woul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Thermal Engineering
سال: 2010
ISSN: 1359-4311
DOI: 10.1016/j.applthermaleng.2010.07.008