Experimental Liver Iron Measurement with the SQUID Gradiometer System
نویسندگان
چکیده
منابع مشابه
High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment
We set up an electronic gradiometer for magnetocardiography (MCG) in an unshielded environment. The electronically balanced gradiometer consists of high-temperature radio-frequency superconducting quantum interference device (rf SQUID) magnetometers. The rf SQUID magnetometers are arranged to form the electronic first-order, four-vector gradiometer, or second-order gradiometer. The output of th...
متن کاملGETMAG – a SQUID mag etic tensor gradiometer for mineral and oil exploration
The system has been demonstrated over a magnetite skarn deposit at Tallawang, near Gulgong, NSW, which is essentially two-dimensional (2D). The 2D structure was important because it allowed an unaliased total magnetic intensity (TMI) survey to be carried out in parallel, from which tensor components could be calculated to directly compare with the tensor components measured with the rotating gr...
متن کاملMeasurement of the Earth’s Gravity Gradient with an Atom Interferometer-Based Gravity Gradiometer
Measurement of the gradient of gravitational fields has important scientific and technical applications. These applications range from measurement of G, the gravitational constant, and tests of general relativity [1,2] to covert navigation, underground structure detection, oil-well logging, and geodesy [3]. This Letter describes the development of a gravity gradiometer whose operation is based ...
متن کاملResponse : Deferasirox ( ICL 670 ) effectively reduces liver iron concentration , whether assessed by biopsy or SQUID
tion in fresh and paraffin-embedded tissue. Clin Chem. 1999;45:573574. 6. Butensky E, Fischer R, Hudes M, et al. Variability in hepatic iron concentration from percutaneous needle biopsy specimens in patients with transfusional hemosiderosis. Am J Clin Path. 2005;123:146-152. 7. Fischer R, Piga A, Harmatz P, Nielsen P. Monitoring long-term efficacy of iron chelation treatment with biomagnetic l...
متن کاملDevelopment of a remanence measurement-based SQUID system with in-depth resolution for nanoparticle imaging.
We present a remanence measurement method using a superconducting quantum interference device (SQUID) to detect trace amounts of magnetic nanoparticles (MNPs). Based on this method, a one-dimensional scanning system was established for imaging. The system was calibrated with 25 nm diameter Fe2O3 nanoparticles (NPs), and the sensitivity of the NPs was found to be 10 ng at a distance of 1.7 cm an...