Experimental Investigation of Condensation Heat Transfer Characteristics of R-134a Vapor in Horizontal Heat Exchanger
نویسندگان
چکیده
منابع مشابه
Experimental Study On R-134A Condensation Heat Transfer Characteristics In Plate And Shell Heat Exchangers
In this study, condensation heat transfer experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-134A. An experimental refrigerant loop has been established to measure the condensation heat transfer coefficient of R-134A in a vertical P&SHE. Two vertical counter flow channels were formed in the P&SHE by stacking three plates of geometry with a corrugated tr...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملExperimental Study on R-410A Condensation Heat Transfer and Pressure Drop Characteristics in Oblong Shell and Plate Heat Exchanger
متن کامل
The Overall Heat Transfer Characteristics of a Double Pipe Heat Exchanger: Comparison of Experimental Data with Predictions of Standard Correlations
The single-phase flow and thermal performance of a double pipe heat exchanger are examined by experimental methods. The working fluid is water at atmospheric pressure. Temperature measurements at the inlet and outlet of the two streams and also at an intermediate point half way between the inlet and outlet is made, using copper-constantan thermocouple wires. Mass flow rates for each stream are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of University of Babylon for Engineering Sciences
سال: 2018
ISSN: 2616-9916,2616-9916
DOI: 10.29196/jubes.v26i6.1004