Experimental investigation into cleanroom contamination build-up when applying reduced ventilation and pressure hierarchy conditions as part of demand controlled filtration

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Demand Controlled Filtration in an Industrial Cleanroom

In an industrial cleanroom, significant energy savings were realized by implementing two types of demand controlled filtration (DCF) strategies, one based on particle counts and one on occupancy. With each strategy the speed of the recirculation fan filter units was reduced to save energy. When the control was based on particle counts, the energy use was 60% of the baseline configuration of con...

متن کامل

an investigation into translation of cultural concepts by beginner and advance student using think – aloud protocols

this research aims at answering the questions about translation problems and strategies applied by translators when translating cultural concepts. in order to address this issue, qualitative and quantitative study were conducted on two groups of subjects at imam reza international university of mashhad. these two groups were assigned as beginner and advanced translation students (10 students). ...

an investigation into iranian teachers consistency and bias in evaluation of students writings

while performance-based language assessment has led to an increased authenticity and content validity in the practice of writing assessment, the reliability of ratings has become a major issue. research findings have shown different reactions by native english speaker (nes) and non-native english speaker (nns) teachers to students’ writings. the focus of this study is on investigating whether i...

0435. Pressure-support ventilation compared to pressure-controlled ventilation in experimental emphysema

Introduction Emphysema is characterized by irreversible enlargement of the airspaces distal to the terminal bronchiole, accompanied by destruction of their walls, and impairment of cardiac function. Acute exacerbation of emphysema leads to increased morbidity, mortality and, in some cases, requirement of invasive mechanical ventilation (MV). So far, no study has compared the impact of pressure-...

متن کامل

Pressure-controlled ventilation and intrabronchial pressure during one-lung ventilation.

BACKGROUND Pressure-controlled ventilation (PCV) has been suggested to reduce peak airway pressure (P(peak)) and intrapulmonary shunt during one-lung ventilation (OLV) when compared with volume-controlled ventilation (VCV). At the same tidal volume (V(T)), the apparent difference in P(peak) is mainly related to the presence of a double-lumen tracheal tube. We tested the hypothesis that the decr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Building and Environment

سال: 2020

ISSN: 0360-1323

DOI: 10.1016/j.buildenv.2020.106861