This research aims to evaluate the effect of using different shear reinforcement details on punching behavior interior slab column connections. A comprehensive experimental program is conducted sixteen specimens having same concrete dimensions 1100×1100×160 mm where depth chosen be less than that stipulated by design codes. The parameters under examination were type arranged in a cross shape perpendicular edges (single leg, multi-leg, and closed stirrups), spacing between stirrups (25 50 mm), extended length covered (300 425 mm). Experimental results showed slabs reinforced with multi-leg or stirrups, even for thickness 160 mm, had an increase capacity up 40% depending stirrup amount. noticeable enhancement ductility was also observed. Slabs vertical single-leg did not exhibit any improvements. finite element analysis further assess tested specimens. comparison test values obtained codes such as ACI 318-19 ECP 203-2018 two give rather underestimated prediction capacity. Doi: 10.28991/CEJ-2022-08-09-015 Full Text: PDF
منابع مشابه
Evaluation of the Efficiency of Shear Studs for Punching Shear Resistance of Slab-Column Connections
متن کامل
Strength of Footing with Punching Shear Preventers
The punching shear failure often governs the strength of the footing-to-column connection. The punching shear failure is an undesirable failure mode, since it results in a brittle failure of the footing. In this study, a new method to increase the strength and ductility of the footing was proposed by inserting the punching shear preventers (PSPs) into the footing. The validation and effectivene...
متن کاملDrift Capacity Models and Shear Strength Degrading Models for Slab-column Connections
Data collected from shake table tests of two, approximately one-third scale, two story flat plate frames utilizing shear reinforcement, as well as data from prior tests, were evaluated to assess the inter-story drift ratios when punching failures occur for reinforced concrete and post-tensioned slab-column connections with and without shear reinforcement. The drift ratios at punching for the sh...
متن کاملInnovative approach to strata reinforcement in coal mines with reference to evaluation cable bolts shear strength
There is an increasing need to determine accurately the strength properties of tendons for an effective ground control on mines and underground structures as well as on modelling simulations. The strength properties of cables, used as cable bolts, have been evaluated mainly by their ultimate tensile strength, as this kind of test can be carried out in the field as well as in the laboratory. Onl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Civil Engineering Journal
سال: 2022
ISSN: ['2676-6957', '2476-3055']
DOI: https://doi.org/10.28991/cej-2022-08-09-015