Structural retrofitting is carried out as an economical alternative to demolishing and rebuilding existing masonry structures. Retrofitting provided offer structural upgrade damage-control. This paper presents the application of oriented strand board type 3 (OSB/3) for unreinforced walls. Out-of-plane bending test in form four-point loading was performed on six The results show that OSB/3 can considerably increase load flexure capacity by (1.4 & 1.8), limiting-toughness (1.6 2.4) overall-toughness (16 10) times compared plain wall subjected out-of-plane (single double-sided) respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

Blast Resistance of Frp Retrofitted Un-Reinforced Masonry (URM) Walls With and Without Arching Action

9 1 TMS Member/Assistant Professor of Civil, Architectural, and Environmental Engineering, University of MissouriRolla, Rolla, MO 65401 2 TMS Member/Professor of Civil, Architectural, and Environmental Engineering, Univ. of Missouri-Rolla, Rolla, MO 65401 3 Former Graduate Research Assistant, University of Missouri-Rolla, Rolla, MO 65401 Blast Resistance of Frp Retrofitted Un-Reinforced Masonry...

متن کامل

A homogenization approach for the limit analysis of out-of-plane loaded masonry walls

This paper addresses the usage of a simplified homogenization technique for the analysis of masonry subjected to out-of-plane loading. The anisotropic failure surface, based on the definition of a polynomial representation of the stress tensor components in a finite number of sub-domains, is combined with finite element triangular elements employed for the upper and lower bound limit analyses. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Construction and Building Materials

سال: 2021

ISSN: ['1879-0526', '0950-0618']

DOI: https://doi.org/10.1016/j.conbuildmat.2020.121358