Experimental Evaluation of Effective Flexural Rigidity in Reinforced Concrete Beams Considering Tension Stiffening Effect

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Tension Stiffening on the Flexural Stiffness of Reinforced Concrete Circular Sections

Within this paper, the assessment of tension stiffening effects on a reinforced concrete element with the circular sections subjected to axial and bending loads is presented. To this purpose, an enhancement of an analytical model already present within the actual technical literature is proposed. The accuracy of the enhanced method is assessed by comparing the experimental results carried out i...

متن کامل

Reliability evaluation of reinforced concrete beams

The purpose of this paper is to evaluate the time-invariant reliability of reinforced concrete beams designed under the provisions of the ACI Building Code. A wide range of practical design situations is considered. The beams are subjected to bending, shear, and torsion. The interaction between shear and torsion is considered via an elliptical failure surface defined in the shear-torsion stress...

متن کامل

Effect of Incorporating Foamed Glass on the Flexural Behaviour of Reinforced Concrete Beams

The flexural behaviour of concrete containing Foamed glass as partial replacement of coarse aggregate is investigated. The coarse aggregate was replaced with 0%, 25%, 50%, 75% and 100% Foamed glass. All other constituents were maintained the same. Reinforced concrete beams were cast using 2 bars of 8mm in diameter in the tensile zone. The density and compressive strength of concrete decreased a...

متن کامل

Flexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars

Fiber-reinforced polymer (FRP) reinforcing bars have aTtracted considerable 0llellli0l1 for applications where corrosion of steel reinforcement is problemaric. Due 10 rhe generally low elastic modulus and poor bond clwracreristics of FRP as coil/pared 10 steel reinforcing bars, the use of FRP results in IGI:i?er crack widlhs under senJice loads. Fiber-reinforced concrete (FRe) is proposed for u...

متن کامل

Experimental Investigations on The Flexural Strength of PET Reinforced Concrete

Due to the rapid industrialization taking place globally, the problems generated are acute shortage of construction material and increasing in productivity of wastes. The production and consumption of plastic and the rate at which solid plastic waste (SPW) are created have increased considerably. Plastics constitute 12.3% of total waste produced most of which is from discarded water bottles. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Korea Concrete Institute

سال: 2005

ISSN: 1229-5515

DOI: 10.4334/jkci.2005.17.6.1033