Experimental assessment and semi empirical estimation of frost accretion—A case study on a spine-finned inverted-V tube array evaporator
نویسندگان
چکیده
Present work focuses on frost accretion in a spine-finned inverted-V tube array evaporator. An experimental evaluation was performed using standard issue, vertical top-mount, 18 cubic feet, 0.5 m 3 , refrigerator. Evaporator temperature distribution, inner airflow velocity, and relative humidity were measured to account for convective phenomena influencing distribution. Frost formation the surface of evaporator visualized thermal microscopic imagery. The images processed machine vision algorithm measure thickness. Complementarily, density vapor mass transfer computed available correlations. estimation function derived from compiled data semi empirical approach, i.e., direct measurements thermophysical substance properties. resulting mathematical expression estimated rate within an error expectancy, RMSE, 0.1479 displayed goodness-of-fit, R-Squared, 0.9029. Based these results, estimation, is proposed as viable approach construct adequate limits new predictions, vis-à-vis performance, ultimately reducing appliance energy consumption via implementing more effective control strategies regarding internal defrosting.
منابع مشابه
Effect of Coil Geometry on Frost-Free Finned-Tube Evaporator Performance
This paper outlines a mathematical modelling approach to predict the steady-state behaviour of finned-coil evaporators. The model was built taking three domains into account: (i) refrigerant flow inside the coil; (ii) heat transfer through the walls; and (iii) air flow through the finned-coil array. The equations were obtained from the mass, momentum and energy conservation principles, mathemat...
متن کاملHeat and Mass Transfer Coefficients Under Frost Conditions In A Finned-Tube Evaporator
The objectives of this study are to provide experimental data and a correlation that can be used in the optimal design of an evaporator under frost conditions. In the present study, we tested both a single stage and a two-stage evaporator with a variation of operating parameters and fin geometry under frost conditions. The effects of tube space and fin alignment on the heat transfer performance...
متن کاملa study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولthe impact of training on second language writing assessment: a case of raters’ biasedness
چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...
15 صفحه اولthe effect of consciousness raising (c-r) on the reduction of translational errors: a case study
در دوره های آموزش ترجمه استادان بیشتر سعی دارند دانشجویان را با انواع متون آشنا سازند، درحالی که کمتر به خطاهای مکرر آنان در متن ترجمه شده می پردازند. اهمیت تحقیق حاضر مبنی بر ارتکاب مکرر خطاهای ترجمانی حتی بعد از گذراندن دوره های تخصصی ترجمه از سوی دانشجویان است. هدف از آن تاکید بر خطاهای رایج میان دانشجویان مترجمی و کاهش این خطاها با افزایش آگاهی و هوشیاری دانشجویان از بروز آنها است.از آنجا ک...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Mechanical Engineering
سال: 2023
ISSN: ['2297-3079']
DOI: https://doi.org/10.3389/fmech.2023.1101425