Experimental and Simulation Study of Resistive Helical HTS Fault Current Limiters: Quench and Recovery Characteristics

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability

Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...

متن کامل

An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques

The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...

متن کامل

selection of resistive and inductive superconductor fault current limiters location considering system transient stability

superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...

متن کامل

simulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water

abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...

Power flow analysis and optimal locations of resistive type superconducting fault current limiters

Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of an SFCL in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Applied Superconductivity

سال: 2021

ISSN: 1051-8223,1558-2515,2378-7074

DOI: 10.1109/tasc.2021.3061958