Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube
In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...
متن کاملExperimental Modal Analysis of a Concrete-filled Tube Arch Bridge
This paper presents the experimental and analytical modal analysis of a concrete-filled (CFT) tube half-through arch bridge, with the span length of 90m, located at the center of Xining City, Qinghai province, China. Dynamic field test was carried out just prior to the official opening of bridge in order to inspect the dynamic characteristics of the bridge and make a baseline record for the fut...
متن کاملCyclic Evolution of Damage and Beam-column Interaction Strength of Concrete-filled Steel Tube Beam-columns
The assessment of response of composite seismic force resisting systems requires accurate nonlinear formulations for the composite members. In this work, reporting the first phase of a NEES project, a three-dimensional distributed plasticity formulation is presented for both circular and rectangular composite concrete-filled steel tubes (CFTs) that includes new constitutive models for the concr...
متن کاملBehavior of FRP-Confined Concrete-Filled Steel Tube Columns
This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap...
متن کاملExperimental Investigation of Multihazard Resistant Bridge Piers Having Concrete-Filled Steel Tube under Blast Loading
This paper presents the development and experimental validation of a multizard bridge pier concept, i.e., a bridge pier system capable of providing an adequate level of protection against collapse under seismic and blast loading but not acting simultaneously . A multicolumn pier-bent with concrete-filled steel tube CFST columns is the proposed concept, and the adequacy of this system is experim...